Preventing Legionella contamination through thermal insulation

Health Tue, Mar 22, 2016 4:55 PM

Preventing Legionella contamination through thermal insulation

Armacell insulation materials protect hot and cold water pipes against unacceptable temperature fluctuations which can occur during the summer when the risk of legionella also rises.

During holiday periods water stagnates in pipework, making HVAC and plumbing systems an ideal breeding ground for hazardous bacteria.

Legionnaires’ disease is an underreported and severe form of pneumonia transmitted by pathogens in water. There is no reliable epidemiological data for the disease in Europe, but estimates vary between 10,000 and 20,000 cases per year.

Contaminated air-conditioners, swimming pools or whirlpools and cooling towers are well-known sources of infection. Errors made in the design and installation of sanitary systems can also lead to a dangerous rise in legionella in drinking water as well as fountains, sprinkler systems and humidifiers for food display cabinets. Therefore, one of the most important preventative measures is to insulate both hot and cold water pipes using suitable materials.

Legionella are bacteria which can get into the drinking water systems of large buildings such as hotels and hospitals through the central water supply. They are particularly likely to multiply in stagnant water at temperatures between 25 and 45°C. The bacteria become hazardous when they are inhaled as small droplets (e.g. as aerosols when taking a shower).

People who are chronically ill or have a weak immune system are at particular risk of contracting Legionnaires’ lung disease, which may be fatal. Because the symptoms are similar to those of flu, the condition is often not diagnosed correctly, with an estimated 95 per cent of cases going unrecognised.

A combination of measures are available to prevent microbial contamination. These include a number of operational, constructional and process-related measures to avoid a harmful multiplication of legionella in drinking water and, where possible, a combination of these should be implemented. Apart from ensuring that the water circulates continuously through the pipework, it is also necessary to prevent unacceptable temperature decreases in hot water pipes and increases in cold water pipes.

According to the European standard BS EN 806-2, pipes for cold drinking water should not follow the same routes or run adjacent to space heating or hot water pipes. Cold water pipes should be protected against heat gain by ensuring sufficient clearance or preferably by insulating properly. Similar requirements apply for hot water pipes to protect them against heat loss.

When hot and cold pipes are laid in one duct or wall cavity, or wherever water is not circulated regularly, Armacell recommends using what is known as 100% insulation, i.e. an insulation thickness which roughly corresponds to the pipework outer diameter. On hot drinking water pipes this not only prevents legionella, but also protects the pipes against unnecessary energy losses. On cold water pipes the insulation provides protection against freezing in cold weather as well as providing protection against unwanted temperature rises.

Suitable insulation materials also prevent unwanted condensation. Because of the risk of condensation, only closed-cell insulation materials with a high resistance to water vapour diffusion should be used on cold drinking water pipes. In practice, accidental damage to insulation has shown that open-cell insulation materials (no matter whether with or without a vapour barrier) do not sufficiently prevent moisture ingress as a result of diffusion.

With open-cell materials the resistance to water vapour diffusion is concentrated on the vapour barrier, so even if the systems are installed carefully, water ingress can often not be avoided. This means that there is a danger of water vapour in the air penetrating the insulation, condensing and saturating the insulation material.

As the material becomes damp, the thermal conductivity increases and insulation properties deteriorate, causing a rise in energy losses. Furthermore, corrosion and other expensive consequential damage can occur.

Armacell insulation materials including AF/Armaflex Class O, Armaflex Tuffcoat and Tubolit protect pipes against temperature increases and decreases. Due to their excellent technical properties, these insulation materials reliably prevent the temperature fluctuations in pipework and at the same time protect the installations against energy losses. The closed-cell material structure also prevents moisture ingress and corrosion of pipework.

Featured News

Specification news
Abloy UK enhances security at St Oswald’s Hospice in...

Abloy UK has provided St Oswald’s Hospice in Newcastle upon Tyne with a secure and...

Read More >>

Specification news
Mapei ensures a safe landing at Northumbria Specialist...

A Mapei coating system has been used to create a helipad at Northumbria Specialist...

Read More >>

BUILDING PRODUCT LIBRARY - LATEST BROCHURES

Valley Through Range Brochure

Valley Through Range
By Filon Products Limit...

Download Now >>

Safer Replacement Starts Below. Filon Fixsafe. Brochure

Safer Replacement St...
By Filon Products Limit...

Download Now >>

A Smart Way to Refurbish Profiled Roofs. Over-Roofing. Brochure

A Smart Way to Refur...
By Filon Products Limit...

Download Now >>

Site Assembled Rooflights & Specialist GRP Sheets Brochure

Site Assembled Roofl...
By Filon Products Limit...

Download Now >>

Factory-Assembled Multi-Layer GRP Rooflights Brochure

Factory-Assembled Mu...
By Filon Products Limit...

Download Now >>

BUILDING PRODUCT DIRECTORY - LATEST PRODUCTS

Magply multi-functional board
Magply multi-functional board

Rainscreen CladdingAs a high performance, multi-functional board Magply features a Magnesium...

Read More >>

Magply recovery and protection boards
Magply recovery and protection boards

Magply recovery and protection boards have been developed to meet the roofing industry needs for a...

Read More >>

Safeshield XT Reflect
Safeshield XT Reflect

Safeshield XT Reflect is an A2-s1, d0 fire rated construction membrane for the use in high risk,...

Read More >>

CONSTRUCTION VIDEOS - LATEST VIDEOS

DDA Handrails – STARGARD
DDA Handrails – STARGARD

The original “warm to the touch” handrail system

Watch Now >>

Introducing the all-new weberpral E
Introducing the all-new weberpral E

A high-performance monocouche render with 22% lower carbon emissions from fossil fuels* - helping...

Watch Now >>

Fortitude™ Steel Railing Systems: Adjustable Off-the-Shelf Balustrade Guide
Fortitude™ Steel Railing Systems: Adjustable Off-the-Shelf Balustrade Guide

Fortitude Steel Railings and Balustrades are one of the most versatile, off-the-shelf, steel...

Watch Now >>